56
Connecting the Output Alarm
In addition to the alarm inputs, this dome will activate an alarm output if an alarm input is
triggered. There are two connections for the alarm output, a common and either a normally open
or a normally closed connection. Again this is a 0 volt switch and could be used for example to
close a circuit to an audible alarm, lighting or other warning devices. Ensure that the switch line
does not carry any voltage. Again this switch remains activated until the input alarm/s have been
cleared/reset.
Technical data table
Power Supply 24V AC 1.7A 50/60Hz
Power Consumption Indoors without heater: 15W Outdoors with heater: 35W
Synchronisation Internal / External
Preset positions 128
No. of Tours / Patrols 6
Pattern record time 200 seconds
Alarms 4 x Input Alarms 1 x Output Alarm
Privacy zone masking 6 (only applies to cameras with this functionality)
Zoom rotation interaction The dome will automatically adjust manual control speed
Auto overturning The camera rotates 180° when vertical position reached
Pan scanning 360° programmable
Pan speed 0° ~ 300° per second
Pan range 360° continuously
Tilt range 0° ~ 90°
Tilt speed 0° ~ 120° per second
Communication RS485
Baud Rate 2400/4800/9600/19200
Fan / Heater Auto (outdoor use only)
Relative humidity 10 ~ 75%
Working Temperature Indoor: 0°C ~ +40°C Outdoor -35°C ~ +55°C
Technical Specification