A+ B-
.....
.....
Main controller
Daisy-Chain connection WITH SHORT SPURS for the RS485 PTZ control signal
(one main radial with very short spurs to each dome off it, keeping the spurs to less than 10 meters)
TIP - The connection of a 120 termination resistor: The termination resistor is ready fitted on the
domes pcb, all you have to do set it is move the jumper from Pins 2 &3 to pins 1 & 2.
STAR method of connection.
In some circumstances you may need to adopt a star configuration for practical purposes. For instance, all the
domes may be so scattered on a large site that running out separate spurs to each dome in a STARarray is
the only practical solution.
So how do you do this in practice?
The termination resistors must be connected to the two domes that are farthest away from each other,
Special Note:
The jumper and dipswitches are
located on the top of the dome
head. To access them push the
dome module up and twist to
release and you will see the
switches as per diagram on the
left.